    The principle, function and terminology of reactive power compensation
    Views:18    2022-08-10

    First, the concept of power

    power is the amount of work done per unit time or the amount of energy converted.

    1, apparent power: apparent power refers to the total power emitted by the generator, which can be divided into active part and reactive part.


    2, active power: active power is the electrical power required to maintain the normal operation of electrical equipment, that is, the electrical power to convert electrical energy into other forms of energy (mechanical energy, light energy, heat energy).


    3, reactive power: is used for the exchange of electric and magnetic fields in the circuit, and used to establish and maintain magnetic fields in electrical equipment, it does not work externally, but is converted into other forms of energy. All electrical equipment with electromagnetic coils, to establish a magnetic field, reactive power must be consumed. Reactive power does not work, but to ensure the transmission of active power must first meet the reactive power of the grid.


    Second, the need for reactive power compensation reasons

    Under normal circumstances, electrical equipment not only needs to obtain active power from the power supply, but also needs to obtain reactive power from the power supply. If the reactive power supply in the power grid is in short supply, the electrical equipment does not have enough reactive power to establish a normal electromagnetic field, and these electrical equipment can not maintain the rated condition, and the terminal voltage of the electrical equipment will drop, thus affecting the normal operation of the electrical equipment.


    However, the reactive power supplied from the generator and high-voltage transmission line is far from meeting the needs of the load, so some reactive power compensation devices should be set up in the grid to supplement the reactive power to ensure that the user needs the reactive power, so that the electrical equipment can work at the rated voltage. Reactive power compensation is to connect the device with capacitive power load and inductive power load in the same circuit, and the energy is exchanged between the two loads, so that the reactive power required by the inductive load can be compensated by the reactive power output of the capacitive load.


    Third, the general method of reactive power compensation

    There are three main methods for reactive power compensation: low pressure individual compensation, low pressure concentrated compensation and high pressure concentrated compensation. The following briefly introduces the scope of application of the three compensation methods and the advantages and disadvantages of using this compensation method.


    1, low pressure individual compensation

    Low voltage individual compensation is based on the demand of individual electrical equipment for reactive power will be a single or more low-voltage capacitor bank dispersed and electrical equipment and connected, it and electrical equipment share a set of circuit breakers, through the control, protection device and the motor at the same time switching. Random compensation is suitable for compensating the reactive power consumption of individual large capacity and connected operation (such as large and medium-sized asynchronous motors), mainly compensating the reactive power of excitation. The advantages of low-voltage individual compensation are: when the electrical equipment is running, the reactive power compensation is invested, and when the electrical equipment is stopped, the compensation equipment is also withdrawn, so it will not cause reactive power backward, with less investment, small space occupation, easy installation, convenient and flexible configuration, simple maintenance, and low accident rate.


    2, low pressure concentrated compensation

    Low voltage centralized compensation refers to the low voltage capacitor connected to the low voltage bus side of the distribution transformer through the low voltage switch, and the reactive power compensation switching device is used as the control and protection device, and the switching of the capacitor is directly controlled according to the reactive power load on the low voltage bus. The switching of the capacitor is carried out in a whole group, and smooth adjustment cannot be achieved. The advantages of low voltage compensation: simple wiring, small operation and maintenance workload, so that reactive power in place balance, so as to improve the utilization rate of distribution, reduce network loss, with high economy, is currently one of the commonly used means of reactive power compensation.


    3, high pressure concentrated compensation

    High voltage centralized compensation refers to the compensation method that the shunt capacitor bank is directly installed on the 6 ~ 10KV high voltage bus of the substation. When the user is far away from the substation at the end of the power supply line and the user has a certain high voltage load, the reactive power consumption of the power system can be reduced and can play a certain compensation role; The compensation device automatically switches according to the size of the load, and the compensation benefit is high.


    Iv. Classification of reactive power compensation devices

    Compensation can be divided into load compensation and line compensation from the range of compensation, and can be divided into inductive compensation and capacitive compensation from the nature of compensation. The methods of shunt capacitive compensation are listed below:

    1.synchronous adjustment camera

    The basic principle of the modulation camera is no different from that of the synchronous generator, which only outputs reactive current. Because it does not generate electricity, it does not need to drag the prime mover, and the adjusting camera without starting the motor has no shaft extension, which is essentially equivalent to a synchronous generator idling in the grid.


    The adjusting camera is the earliest reactive power compensation device used in the power grid. When the excitation current is increased, its output capacitive reactive current increases. When the excitation current is reduced, the output capacitive reactive current is reduced. When the exciting electric field is reduced to a certain extent, the output reactive current is zero, and only a small active current is used to make up for the loss of the adjusting camera. When the exciting current is further reduced, the inductive reactive current is output.


    The adjustable camera has a large capacity, is not sensitive to harmonics, and automatically increases the output reactive current when the grid voltage drops, so the adjustable camera plays an irreplaceable role in the reactive power safety of the grid.


    Due to the high price, low efficiency and high operating cost of the adjusting camera, it has been gradually replaced by shunt capacitors. However, in recent years, due to the importance of reactive power safety in the power grid, some people advocate the re-use of the adjusting camera.


    2, parallel capacitor

    Shunt capacitor is the main reactive power compensation method at present. Its main characteristics are low price, high efficiency, low operating costs, and high reliability in the case of perfect protection.


    In high-voltage and medium-voltage systems, fixed-connected shunt capacitor banks are mainly used, while in low-voltage distribution systems, automatic reactive power compensation devices that automatically control capacitor switching are mainly used. The structure of automatic reactive power compensation device is varied and suitable for a variety of different load conditions. The low voltage automatic reactive power compensation device will be described in detail.


    The main disadvantage of shunt capacitors is their sensitivity to harmonics. When the power grid contains harmonics, the current of the capacitor will increase sharply, and it will resonate with the inductive components in the power grid to amplify the harmonics. In addition, the shunt capacitor is a constant impedance component, and its output reactive power decreases when the power grid voltage drops, so it is not conducive to the reactive power safety of the power grid.


    3. SVC

    The full name of SVC is static reactive power compensation device, and the two words static are corresponding to the rotation of the synchronous adjustment camera.

    The International Big Grid Conference defines SVC as seven subcategories:

    a, mechanical switching capacitor (MSC)

    b, mechanical switching reactor (MSR)

    c, self-saturated reactor (SR)

    d, thyristor control reactor (TCR)

    e, thyristor switching capacitor (TCR)

    f, Thyristor (TSC)

    g, self-commutation or grid commutation converter (SCC/LCC)


    According to the above subcategories, we can see: except for the adjustable camera, the reactive power compensation devices with inductors or capacitors are almost defined as SVC. Therefore, at present, a large number of materials or advertisements appear in the word "SVC", the reason is no more than two: one is that the author does not understand the definition of SVC, and the other is to confuse the letter combination that ordinary people do not understand.


    At present, the main products of SVC advertised in the domestic market are thyristor control reactor (TCR) and thyristor switching capacitor (TSC). As for TSC, we will discuss it in another article, and only briefly introduce the thyristor controlled reactor (TCR) here.


    The basic structure of TCR consists of a set of capacitors connected in parallel in the line and a set of thyristor controlled reactors connected in parallel in the line, and the capacity of the reactor is usually designed to be the same as that of the capacitor. Since the reactor is controlled by a thyristor, its inductive reactive current can change. When the thyristor is turned off, the reactor has no current, while the capacitor is fixed, so the compensation amount of the whole device is the largest. When the conduction Angle of the thyristor is adjusted, the inductive current of the reactor will offset part of the capacitor current, so the compensation amount is reduced. The smaller the compensation amount, when the thyristor is fully passed, the reactor current will cancel out the capacitor current, and the compensation amount is 0. The fixed capacitor bank must be designed as a filter or equipped with another filter.


    In summary, it can be seen that the structure of TCR is complex and the loss is large, but it has the characteristics of continuous adjustable compensation amount, and it is also applied in high pressure systems.


    4. STATCOM

    STATCOM is a device that uses fully controlled high-speed power electronic devices such as IGBT, GTO or SIT as switches to control current. Its basic working principle is as follows:


    By detecting the electrical parameters of the system, a sinusoidal current waveform with appropriate amplitude and the same phase as the power supply voltage is predicted. When the instantaneous current of the system is greater than the predicted current, the STATCOM will absorb the part greater than the predicted current and store it in the internal energy storage capacitor. When the instantaneous current of the system is less than the predicted current, STATCOM will release the energy stored in the capacitor to fill the part that is less than the predicted current, so that the compensated current becomes a sine wave in phase with the voltage.


    According to the working principle of STATCOM, theoretically STATCOM can realize real dynamic compensation, which can be applied not only in inductive load situations, but also in capacitive load situations. And can be harmonic filter, play the role of filter. However, the actual STATCOM cannot meet the theoretical requirements due to technical reasons, and because the switch operating frequency is not high enough, it will also output harmonics to the power grid.


    The structure of STATCOM is very complex, expensive, poor reliability, and large loss. At present, STATCOM is still in the research and trial stage, and has no practical application value. The compensation of reactor (TSR) can be divided into series compensation and parallel compensation.


    5. The advantages of reactive power compensation

    1.According to the power factor of the electrical equipment, the power loss of the transmission line can be calculated. Through the field technical transformation, the power factor below the standard requirements can be reached and the purpose of power saving can be realized.


    2.the use of reactive power compensation technology to improve the power factor of low-voltage power grid and electrical equipment is an important measure to save power.


    3.Reactive power compensation, it is the use of reactive power compensation equipment jacquard necessary reactive power, in order to improve the power factor of the system, reduce energy consumption, improve the power grid voltage quality, stable equipment operation.


    4.Reduce power loss, general factory power wiring according to different lines and load conditions, the power loss of about 20%-30%, the use of capacitors to improve the power factor, the total wave is reduced, can reduce the power supply flow and power loss.


    5.Improve the quality of power supply, improve the power factor, reduce the total load current and voltage drop, the secondary side of the transformer installed capacitance can improve the power factor to improve the secondary side voltage.


    6.Extend the life of the equipment, improve the power factor after the total line current is reduced, so that close to the saturation of transformers, switches and other machinery and equipment and line capacity load is reduced, so you can reduce the temperature rise to increase the life (every 10 degrees Celsius temperature reduction, life can be extended by 1 times).


    7.Finally meet the monitoring requirements of the power system for reactive power compensation, eliminate the penalty caused by too low power factor.

    8.Reactive power compensation can improve power quality, reduce power loss, tap the potential of power generation equipment, reactive power compensation to reduce the user's electricity expenses, is a less investment, quick effect of energy-saving measures.

    9.The influence of reactive power compensation technology on the low-voltage distribution network of electric units and the economic and social benefits brought by improving the power factor, determining the compensation capacity of reactive power, ensuring that the compensation technology is economic, reasonable, safe and reliable, and achieving the purpose of saving electric energy.


    Use the
    Views:15    2022-08-10

    On February 20, in Shuixigou, Nanshan, Urumqi City, Xinjiang Urumqi Power Supply Company's professional maintenance personnel innovated the "insulation rod + insulation platform" operation method, successfully eliminated the fault of the 10-kV travel water second-line equipment, lifted the alarm for the safe operation of the line, and ensured the uninterrupted power supply to users along the line.


    On the 19th, the staff of Urumqi Company found that the 53 pole of the 52 branch line was torn due to the Angle iron of the pole top support, and the middle phase wire and insulator fell and became entangled with the side wire. The company decided to try to use the "insulation rod + insulation platform" operation method to complete the elimination task. In order to ensure the safety and feasibility of the operation, the staff has developed a special construction plan and strict safety measures. On the 20th, the company sent experienced operators to the scene, and after more than two hours of work, the hidden danger of the line was eliminated.


    It is understood that the "insulation rod + insulation platform" operation method is a new comprehensive non-power outage operation method developed by Urumqi Company, which is suitable for live work projects in mountainous areas, farmland, roads and other conditions that do not meet the requirements of insulation bucket arm vehicle passage, insufficient working space and large site slope. The popularization and application of this method can further expand the coverage of live work in the distribution network, improve the popularity rate of live work, reduce the power outage of users in a wider range, and improve the reliability of power supply. At the same time, the ownership cost is low, the size is small, the installation method is simple, the operation is no noise, no oil consumption, and is not affected by the surrounding environment of the work site and the restrictions of terrain conditions.

    Demand growth drives the transformation of transmission and distribution enterprises
    Views:16    2022-08-10

    "From the installation of power equipment, investment scale, power equipment is divided into two parts, one part is power supply construction equipment, that is, power generation equipment, including water, fire, nuclear, wind, light and other power generation equipment, the other part is power grid construction equipment, including transmission, distribution, electrical equipment and so on." In 2015, the absolute value of power generation equipment production increased, but the growth rate is gradually slowing down. And the output growth of transmission and distribution equipment is increasing." On February 17, at the "Toshiba China Forum 2017" industrial electrical sub-forum, Wang Kun, assistant president of the China Electrical Appliances Industry Association and Secretary-General of the Smart grid Equipment Committee, said.


    In recent years, under a series of favorable policies such as distribution network investment, rural network transformation, urbanization construction, and distribution transformer transformation, the demand for transmission and distribution equipment has an obvious upward trend, and has experienced a highly developed process. This also requires power transmission and distribution enterprises to transform as soon as possible to meet market demand.


    The demand for power grid equipment exceeds that for power supply equipment

    Recently, the National Energy Administration released the 2016 national power industry data. From the perspective of power grid investment, from January to December 2016, the national power grid investment reached 542.6 billion yuan, an increase of 16.9%, accounting for 60.8% of the entire power investment.


    "It can be seen that the speed of grid construction has exceeded the speed of power supply construction. In addition, according to statistics, the share of power transformation and distribution equipment below 110 kV has exceeded 58%, an increase of 35.9%, and the growth rate of power grid construction is 16.9%, which is not difficult to see by comparison, the growth rate of low-voltage distribution products and the growth rate of power grid construction." Wang Kun analysis said that this shows that on the one hand, the investment intensity of China's power grid construction has been greater than the power supply construction, on the other hand, in the power grid construction investment intensity, the share of low-voltage distribution equipment is more than half, and the growth rate is greater than 110 kV transmission equipment.


    In Wang Kun's view, it is normal for the investment intensity of power grid construction to be greater than that of power supply construction. He gave a reason. First of all, in the power system, the electricity sent out must be output and distribution, and the demand for transmission and distribution equipment will increase with the increase of power supply construction. Secondly, grid construction lags behind power supply construction. The lag period is usually between 2 and 4 years. Now China's power supply construction has entered a bottoming process, 2015 ~ 2016, China's power transmission and transformation equipment has experienced a rapid development process, but the next 2 ~ 4 years later, the growth rate of power grid construction will also slow down, the fundamental reason is that social electricity demand is declining.


    However, the construction of smart grid characterized by green and energy saving has always remained unchanged. Therefore, it is necessary for power transmission and transformation equipment enterprises to keep pace with The Times and change their concepts. "From the perspective of equipment, equipment is the carrier of power grid technology and the new structure of power grid, without the support of equipment, any technology, policy, development trend is water without a source." "Said Wang Kun.


    Therefore, in the process of promoting the construction of smart grid, China has introduced some policies related to power transmission and transformation equipment, such as the "Action Plan on the construction and transformation of distribution network (2015 ~ 2020)" proposed that during the "13th Five-Year Plan" period, China's distribution network construction and transformation investment is not less than 1.7 trillion yuan, and put forward requirements for the upgrade and transformation of distribution transformers. Another example is the "Energy efficiency Improvement Plan for distribution transformers (2015-2017)", which proposes that by the end of this year, the proportion of efficient distribution transformers in the network will be increased by 14%, and the cumulative promotion of efficient distribution transformers will be 600 million kVA. Among them, the new incremental promotion is not less than 350 million kVA.


    Transmission and distribution equipment enterprises need to be guided by these policies and accelerate research and development. Wang Kun said that the future of power equipment technology will have four development trends, first, the new normal of economic development requires that the power equipment manufacturing industry must change to quality and efficiency. At present, the power distribution, transmission equipment industry overcapacity, with the country's "three to one to make up one down", capacity will become the "thirteen five" a keynote; Second, the new round of scientific and technological revolution and industrial revolution requires the transformation of the power equipment manufacturing industry to intelligence; Third, the transformation of manufacturing power to power requires that the power equipment manufacturing industry must implement innovation-driven strategy; Fourth, the overall strategic layout of the "Belt and Road" requires that the power equipment manufacturing industry must accelerate the implementation of "going out".


    Intelligent manufacturing into power transmission and transformation equipment enterprises competitive advantage


    "Recently, major countries in the world have launched national development strategies for intelligent manufacturing, taking the development of intelligent manufacturing as the strategic core. From the current point of view, the new generation of industrial revolution represented by intelligent manufacturing will be the key to releasing future competitiveness, but also the key to the industry reshuffle." Wang Kun pointed out the importance of intelligent manufacturing.


    For power transmission and transformation equipment, intelligent manufacturing in a broad sense, including the product manufacturing part, refers to the design, processing, assembly, experiment, testing, operation and other intelligent, on the other hand refers to the intelligent function of the equipment itself, such as intelligent transformers, intelligent switches.


    "For power transmission and transformation equipment, the current design and manufacturing of core components is difficult. The use environment is complicated, and the need of remote inspection and maintenance on site is urgent. For high-voltage and ultra-high-voltage power transmission and transformation equipment manufacturers, there is a need for unified and coordinated use of resources, unified technical management, and collaborative manufacturing processes." "Said Wang Kun.


    For distribution equipment, the industry has proposed intelligent manufacturing system design characterized by flexible manufacturing to achieve customized manufacturing. At present, the profit margin of power distribution equipment enterprises is very low, affected by material cost fluctuations, rising labor costs, market terminal product price reduction and other factors, the operation and manufacturing mode of existing products does not change, then the profit margin will become more and more obvious, which will have a greater impact on the industry. It is necessary for transmission and distribution enterprises to realize intelligent product design as soon as possible, flexible management of intelligent manufacturing of low-voltage distribution equipment, including product life cycle management, digital product design and production layout simulation.


    So, how to achieve flexible manufacturing? Wang Kun proposed that on the premise of digital design, a flexible automated production line should be established to achieve the balance of production process, system operation, logistics layout and production rhythm, and a digital workshop transparent information process management system.


    At present, many domestic transmission and distribution equipment enterprises are taking the road of intelligent manufacturing. For example, Tianshui Great Wall Switch Factory Co., Ltd. implemented the "medium pressure air insulation switchgear manufacturing digital workshop", Zhongtian Technology intelligent manufacturing workshop, Zhejiang Yueqing low-voltage electrical intelligent equipment industrial cluster.